Arrived for furnace check today. Static is passing. Heat exchanger looks good. Carbon monoxide test was 0ppm. All electrical is in range. Filters are clean. There is a good temperature rise. System is running at departure. Thanks for choosing LBA.
12/8/25 - Completed a full heating maintenance on six RTU’s. The filters were changed and proper operation was tested. Overall, all units were in good condition, they were all running well, and there were no issues found at this time.
Arrived for humidifier not working. Found humidifier is working. Today you signed up with our membership plan. Thanks for choosing LBA.
Installed new gas valve. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Lead Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.
Dispatched for no heat on main floor system. System had code for lockout due to 3 * attempt and no flame detected. After multiple test on the gas valve and other components. It was determined to have a faulty two stage gas valve. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Lead Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.
11-26-25 The gym front lobby no heat. We just put in some dampers and also made some adjustments to the bypass damper. Today I found the RTU furnace ignition board flashing the code for high limit trip three times. I reset the rooftop unit for mechanically it’s working. I did take the W-2 off of the board so only runs first stage heating. I am getting a heating supply air temperature about 110° I closed the bypass damper to test my temperature rise curly I am at 30°, which is a little low. I made adjustments on the bypass damper to stay closed. When both zones dampers are opened. The the bypass camper was opening when there was a call to both zones so potentially there was a little bit hotter than normal, which may have caused that limited trip. So I made adjustments so that the bypass damper is closed both stones are calling There has been issues with that limit switch. I believe Jon found the limit switch taken out. I’ll check with him. So using frist stage heat, may or may not
Plumbing service
Completed furnace maintenance and inspection. I cleaned flame sensors and wipe down furnaces. I checked amp draws and components. I tested air pressure and temp splits. I fixed duct run running into the humidifier so the humidifier damper works. I changed out both air filters. Furnaces are operating within manufacture specifications at departure.
Arrived to do a multi system performance maintenance. Set up for combustion analysis temperature split and static pressure tests for each system individually. Found that all systems in the basement are operating with failing static pressure. Verified operation of all mechanical and electronic components of each furnace. Checked each systems fan for cleanliness and to see if there is any play in the bearings. All fans are collecting dust but are not to the point of needing cleaned. Checked each systems heat exchanger to ensure proper venting of flue gas. Verified operation of all humidifiers. Each systems humidifier is in need of a water panel, due to calcium buildup and bacterial growth. With homeowners approval replaced all humidifier panels and furnace filters. All furnaces and humidifiers are operational at this time.
11-24-25 First floor, gym and lobby area heating cooling system. Today, Tyler, Collin, and myself installed two zone dampers and made repaits on the bypass damper. We cycled the system in all modes also confirming proper pressure at .06 inches on the bypass damper.
Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Checked systems heat exchanger to ensure proper venting of flue gas. Performed an electronic gas leak search. Verified operation of the humidifier. With homeowners approval replaced the humidifiers steam canister. Furnace and humidifier are operational at this time.
Arrived to do a performance maintenance. Upon arrival noticed flue condensation leaking out of the exhaust piping. Set up for combustion analysis temperature split and static pressure tests. Verified operation of all mechanical and electronic components of the furnace. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the fan is coated in dust debris. Checked systems heat exchanger to ensure proper venting of flue gas. Verified operation of the humidifier. Found the humidifier panel is coated in calcium buildup. Spoke with homeowner about the system. With homeowners approval replaced the panel in the humidifier. Furnace and humidifier are operational at this time.
This task will be digging up the existing line removing the thin wall pvc and adding the proper schedule pipe required by code. We will ensure the correct fall and support per code and will scope the line to ensure the connections are secure.
11-19-25 Picked up two zone damper controllers to be installed later on this week.