Real-time Service Area
for Liberty, MO


Map of Liberty, MO
Tory P.

Tory P.

Swapped out gas control valve sleight repipe

Near Shannon Dr, Liberty, MO 64068

Map of Liberty, MO
Tory P.

Tory P.

Swapped out burner assembly for new one. Pilot light stayed lit. Thank you for choosing LBA

Near Shannon Dr, Liberty, MO 64068

Map of Liberty, MO
Rainer M.

Rainer M.

Need to do a duct clean along with blower motor clean

Near Tudor Ln, Liberty, MO 64068

Map of Liberty, MO
Calvin  W.

Calvin W.

Dispatched for annual AC tuneup. At arrival system is operating. During the tuneup, I checked compressor, fan and capacitor. Also, during the inspection we checked pressures, static pressure, and temperature split. All components of the AC are all operating with manufacturer specs. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.

Near Robin Ct, Liberty, MO 64068

Map of Liberty, MO
JJ H.

JJ H.

Bad stat. Replaced it, AC is up and cooling. Thank you for choosing LBA services!

Near Current Pl, Liberty, MO 64068

Map of Liberty, MO
Jared B.

Jared B.

We diagnosed his issue for bad airflow but he did not want to fix it. I should’ve charged a diagnostic fee but I didn’t know we had one until after

Near Little Blue Ct, Liberty, MO 64068

Map of Liberty, MO
JJ H.

JJ H.

Airflow issue is the reason system is keeping up. Thank you for choosing LBA services!

Near Little Blue Ct, Liberty, MO 64068

Map of Liberty, MO
Camron  K.

Camron K.

B

Near Shannon Dr, Liberty, MO 64068

Map of Liberty, MO
Cameron W.

Cameron W.

Estimate for water heater under warranty

Near Shannon Dr, Liberty, MO 64068

Map of Liberty, MO
Patrick  K.

Patrick K.

Arrived to remedy a system that’s unable to keep up in the heat. Tested systems airflow and temperature split. Found that the system is cooling 18 degrees, when we only ask 20 out of it. Tested systems airflow and found that both cooling systems are operating with failing static pressure. Found that both systems fans are dirty and impeding the amount of air the system is capable of moving. Went outside and found bone condenser coil heavily impacted with debris and the other one wasn’t exactly clean either. Dirty condenser coils will impede the amount of cooling a system is capable of producing. Spoke with homeowner about solutions. Homeowner declined repairs at this time. Systems are operational upon departure.

Near Bur Oak Dr, Liberty, MO 64068

Tory P.

Tory P.

For this job as I was doing my inspections the customer brought to my attention of a leak from his 3rd floor shower down to his basement. Gave him a quote on a shower valve that can be subject to change because he wasn’t ready to open the wall up. Also quoted on new prv and sump pump. Thank you for choosing LBA

Near W Kansas St, Liberty, MO 64068

Johann A.

Johann A.

Na

Near W Kansas St, Liberty, MO 64068

Cameron W.

Cameron W.

EST to dig

Near NE 137th St, Liberty, MO 64068

Calvin  W.

Calvin W.

Dispatched for annual AC tuneup. At arrival system is operating. During the tuneup, I checked compressor, fan and capacitor. Also, during the inspection we checked pressures, static pressure, and temperature split. All components of the AC are all operating with manufacturer specs. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.

Near Norton Ave, Liberty, MO 64068

 .

.

Today the N.W. unit’s thermostat was blank when I arrived, I accessed the roof and discovered that the disconnect for the unit was on however there was no electricity to it. The breaker for this unit at the indoor breaker box was tripped. I reset the breaker and the unit returned to operation. I checked multiple items that would cause this breaker to trip and did not discover a cause. The system was cycled twice and I monitored it while operating for 20mins. There have been storms moving through the area. At the end of my diagnostics today another storm passed through. I let the staff know where the breaker is for this unit and that if this occurs again to let us know. Thank you, Jon Tech notes: Daiken packaged (nat gas), m/n DSG0600903DXXXAA, s/n 1708263563, DT 20 (71-51) Comp 10.06A (rated 16A), inrush amps Outdoor fan motor 1.2A (rated 1.4A), bearings good Outdoor fan capacitor 10.15uf (rated 10uf) Ecm blower motor 2.19A (rated 6A), bearings good Contactor: not pitte

Near NE 96th St, Liberty, MO 64068