Dispatched for furnace tune-up. The components that are tested during the tuneup are heat exchanger, flame sensor, igniter, blower wheel, inducer, temp split and combustion in the heat exchanger. All components of the furnace are with in range of manufacture specifications. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Lead Service tech Calvin. If I provided a positive or five star experience. I’d appreciate you sharing your thoughts in a review.
Returned to install tankless water heater. Upon arrival removed and hauled away old power vent water heater. Installed new Navien 240A2 tankless water heater. Reworked gas & water lines to accommodate for new tankless water heater. Ran condensation line to floor drain. Tested everything for gas & water leaks. No leaks detected. 15 year heat exchanger warranty 5 year parts warranty 1 year labor warranty
Clean house and uv
We cleaned 2 mini split condensers on top of a service room they are all cleaned out now.
Performed Lite heating maintenance on 3 RTUs. Changed filters and all units running at time of departure.
Went for a humidifier issue. Noticed the water panel was dry. Tested solenoid valve and is operating. Did notice port was dirty did clean it. Allowing for water to flow. Humidifier is up and running. Did also give quote for a duct cleaning. Customer approved and will be booked for tomorrow. Duct cleaning and UV light with the holiday promotion. Payment will be collected once job is finished. Thank you for choosing LBA services-Johann
Went for a maintenance call today for heat. Tested for static pressure system is passing when in heat. All electrical components are passing for manufacture specifications. Did notice inducer motor amps are close to max. Will, recommend to have replaced. Did a combustion test is within range. Inspected heat exchanger no cracks/leaks were detected. Checked temp split and is passing for specifications. Did replace filter for customer. Cleaned flame sensor and pressure switch hose. System is up and running before departure. Thank you for choosing LBA services-Johann
Provided estimate for tankless. Tankless will include expansion tank as well.
replaced water heater and dishwasher
Customer called in about water heater not working. Upon arrival blower motor on water heater was running non stop and gas control valve lights are all on. Informed customer it could be a bad blower motor is computer issue with gas control valve or main computer. Talked to tech support and tech support confirmed that gas control valve is faulty. Gave customer options and customer wants to discuss with wife wether to repair or replace water heater.
Arrived to perform a mini split cleaning. Remove the mini split powerhead cover and filters as well as air directing veins. Applied bib over the coil and blower assembly of the mini split powerhead. Rinsed excess debris from the unit. Applied foam cleaner to the coils and blower wheel. Wiped problem, spots and Rins away the cleaning solution. Set system to heat to allow the fan to spin and dry the unit faster. Applied covers to unit and cycled power multiple times to ensure the system is running and heating and cooling properly. System is functioning properly at this time.
Installed new full system
Arrived for furnace check today. First we got the thermostat set up correct. Heat exchanger looks ok. Carbon monoxide test was 0ppm. Blower wheel is clean. There is a good temperature rise. Electrical is in range. Thanks for choosing LBA. Have a good trip!
Arrived to remedy and system. Upon inspection of the system, found a fault code pertaining to the system pressure switch. Verified operation of the pressure switch and verified that it is relaying its signal back to the control board. Control board is still displaying the fault on the pressure switch circuit. Tested other components of the safety system. System was providing different vault codes for each different test. This tells me the system is functioning properly on each of those circuits. Determine that the issue is the furnace control board. Spoke with homeowner about repair solutions. With homeowners approval reached out to a field supervisor to provide repair and replacement options. Homeowners will be getting a new furnace installed tomorrow. Left space heaters to heat the home in the meantime.
…