Real-time Service Area
for Olathe, KS


Map of Olathe, KS
Camron  K.

Camron K.

B

Near N Keeler St, Olathe, KS 66061

Map of Olathe, KS
Cameron W.

Cameron W.

Sold job

Near N Keeler St, Olathe, KS 66061

Map of Olathe, KS
JJ H.

JJ H.

The cause of the water heater back drafting is due to negative pressure from the return air on the hvac system. It is significantly short on CFM and is trying to pull air from other places. When the system isn’t running the water heater is drafting fine. Thank you for choosing LBA services!

Near W 158th Ct, Olathe, KS 66062

Map of Olathe, KS
Johann A.

Johann A.

Ins 80% full system, double return, customer tstat, re-built humidifier, and re did flue.

Near S Alcan St, Olathe, KS 66062

Map of Olathe, KS
Rainer M.

Rainer M.

This pricing includes a blower motor removal and clean option if you go with just a duct clean price would needed to be adjusted.

Near W 150th Terrace, Olathe, KS 66062

Map of Olathe, KS
JJ H.

JJ H.

Customer is selling the house

Near W 157th St, Olathe, KS 66062

Map of Olathe, KS
Jared B.

Jared B.

Sold standard full system, reinstall hum and UVC, adding a return grille as well and installing Tuesday 7/8

Near S Alcan St, Olathe, KS 66062

Map of Olathe, KS
Johann A.

Johann A.

Went for an out. Blower motor was not operating. Blower was failing and not getting power. Did have a comfort specialist out, and will have solutions for customer. Did leave window unit for customer. Thank you for choosing LBA services-Johann

Near S Alcan St, Olathe, KS 66062

Map of Olathe, KS
Andrew S.

Andrew S.

Arrived for ac check today. Started at furnace and checked static pressure, it is passing. Blower wheel is clean. Motor amps are within range. Coil is clean. There is an 18 degree temp split. At the condensing unit all pressures and charge look good. All electrical components are running within range. I rinsed coil clean. There is some dust build up in ducts. I installed smart ac today. System is running upon departure. Thanks for choosing LBA.

Near S Acuff St, Olathe, KS 66062

Map of Olathe, KS
Dre S.

Dre S.

Customer joined membership program and went with repair options . They are aware of the other issues with the system that have permanent irreversible damage

Near W 123rd Terrace, Olathe, KS 66061

Andrew S.

Andrew S.

Arrived for ac check today. Started at furnace and checked static pressure, it’s failing. It’s running at twice the rated amount. Blower wheel is very dirty. Blower motor amps are running high. There is only a 14-15 degree temp split. It needs to be 20. The evaporator coil is rusting out. There is bacterial growth on coil pan. At the condensing unit I rinsed coil clean. Pressures and charge don’t look to bad. The contactor is burnt and pitting. The capacitor has failed. My field supervisor is out to verify my findings. With approval I replaced the capacitor and contactor. System is running upon departure. Thanks for choosing LBA.

Near W 123rd Terrace, Olathe, KS 66061

Jeremy O.

Jeremy O.

-I isolated hot and cold lines to master bath lav faucet and observed that the hot water supply is still dripping from lav faucet. -I took off handle and tightened cartridge on hot side -Haven’t seen a drip at this moment Thanks for choosing LBA Services! Your technician

Near W 110th St, Olathe, KS 66061

Patrick  K.

Patrick K.

Arrived to remedy an inoperable system. Turned system on and found that it would start up and run as designed. Checked the evaporator coil to ensure that the system is not freezing up. Checked system temperature split. Went outside and checked power consumption of the fan and compressor. Checked system refrigerant levels. All tests are within spec. When checking the capacitor in the condenser found that a wire connection was very loose and could have caused an amperage spike.

Near S Summit St, Olathe, KS 66062

Johann A.

Johann A.

Na

Near S Sheridan Bridge Cir, Olathe, KS 66062

Tory P.

Tory P.

Estimate