System was not cooling because the air was not passing through the evaporator coil. This is because the filter was so dirty that not enough air was going over the evaporator coil, causing it to freeze and because it was freezing and turning into an ice block no air was getting past. We’re letting it thaw now. I’ve cleaned up what water I can. Hopefully we have no long-term damage to the heat exchanger from the water dripping down or the evaporator coil from the freezing. And hopefully none of that water and makes its way to the control board.
1-patch on the return
Customer called for frozen coil. We did air flow improvements previously, unfortunately air flow is t exactly balanced and we are drawing too cool of air in the night causing a hyper cooling situation and causing coil to freeze and system drop out on low pressure. Air flow will need reevaluated by design team to correct issue. We will assess and return to make corrections.
Needs a vent clean and a blower motor clean. In a small patch on the return.
Lennox is shipping evaporator coil to our shop, will arrive by Monday. Customer is on schedule for Wednesday morning
Went for a tune up today. Tested for static pressure, system is failing when in cool. Checked evaporator coil does have rust at the bottom of coil. Checked temp split below specifications, as well for refrigerant charge. All electrical components are passing for manufacture specifications. Did clean condenser unit and filter provided from customer. Will have supervisor revisit for refrigerant issue. Thank you for choosing LBA services-Johann
Completed ac inspection, all components tested to manufacture specifications. Recommended a duct cleaning and emailed quotes over to customer and he is going to let us know when he can do that.
.
Completed ac inspection. All components tested to manufacture specifications. No recommendations at this time.
A-1 Sewer & Septic Service performed the following services: - Replaced a broken section of cast iron pipe, through the foundation wall, to the existing PVC just outside the foundation wall that runs to the septic tank. an additional 7’ away. - Hydraulic cemented the core hole through the wall for waterproofing and backfilled to rough grade. - Hauled off job-related spoils.
Sold job
B
Arrive for ac maintenance today. Started at furnace and checked static pressure, it is passing. Blower motor amps are good. Blower wheel is clean. Indoor coil is clean. There is a 24 degree temp split. At the condensing unit all pressures and charge look good. All electrical components are running within manufacturing specs. I rinsed the coil clean. System is running upon departure. Thanks for choosing LBA.
Arrived for ac maintenance today. Started at furnace and checked static pressure, it is passing. Blower motor amps are good. Blower wheel is clean. There’s a 22 degree temp split between supply and return air. I changed furnace filter. At the condensing unit all pressures and charge look good. All electrical components are running within manufacturing specs. I rinsed coil clean. System is running upon departure. Thanks for choosing LBA.
Installed sensors